Home › Retaining Wall Calculator

Concrete, masonry & paving

Retaining Wall Calculator

Estimate the materials for a segmental block retaining wall. Enter the wall size and block size, how many courses are buried below grade, and the size of the gravel base and drainage zone.

US & metric · No account needed · Calculations stay in your browser

View the measurement guide
Measurement guideNot to scale
Measurement guide for Retaining Wall CalculatorExposed height, buried courses, base and drain-stone zones are distinct inputs. No stability check is performed. All geometry is schematic and does not depict a structural design.ExposedheightDrain zoneBaseBuried
Exposed height, buried courses, base and drain-stone zones are distinct inputs. No stability check is performed. View detailed drawings
  1. MeasureEnter your project measurements.
  2. MatchCheck product values and allowances.
  3. ReviewCheck quantities, inputs and sources.

Your project

Change an input to update the estimate. Check units and product assumptions before ordering.

Units
Wall
Blocks
Gravel
Product data
Product value source

Set base and drain-stone densities independently using the same condition as the specified layer volumes. Values stay in this tab; reset restores planning assumptions.

YOUR MATERIALS

Purchase estimate

Materials only, not retaining-wall design. Curves, corners, steps, geogrid, soil bearing, earth pressure, sliding, overturning, surcharge loading, and actual drainage design are excluded. Even low walls can require engineering. Product defaults are planning assumptions. Use the chosen product data sheet or supplier test for the actual application; reset restores defaults.

Detailed drawings & current dimensions

Not to scale. Dimension values follow your inputs; the drawing proportions do not. Displayed numbers may be rounded. This is a measurement aid, not an approved construction detail.

Elevation — exposed and buried courses

Elevation — exposed and buried coursesSchematic measurement view, not to scale. Lettered dimensions correspond to the current input list. Layer heights and repeated items are illustrative, not design details.ABCExposed height above the ground line

Section — entered material zones

Section — entered material zonesSchematic measurement view, not to scale. Lettered dimensions correspond to the current input list. Layer heights and repeated items are illustrative, not design details.BFDEDrain stoneBaseBuried

Current calculator inputs

Hidden shape inputs are omitted. These values are entered assumptions, not independently verified product data.

Keep this estimate

Export the current estimate as a visual report. Print it or save as PDF. Local saving is optional; no account is required.

Back up or restore saved projects

Data files (JSON) are for restoring editable projects, not for reading or printing. They include saved projects only; save the current estimate first if you want it in the backup.

UNDERSTAND THE ESTIMATE

A material model is not a stable-wall design

Wall blocks, caps, base stone and drain stone are separate quantities. Enter the buried courses and layer geometry from the chosen block system and project details; the calculator does not determine safe embedment.

Base and drainage densities can be changed separately. The drainage volume uses the model's entered rectangular zone; real batter, stepped foundations and drainage geometry can differ. Cap pieces do not automatically receive the wall-block waste percentage.

Try a checked example

For entered 6 m length, 0.9 m exposed height, 30 × 10 cm block faces and one buried course, the model counts ten courses of twenty blocks, then 5% allowance: 210 blocks. Entered layer geometry gives 0.54 m³ of base and 1.8 m³ of drain stone. At the two stated example densities, masses are 0.972 and 2.7 tonnes. None of these inputs establishes wall stability.

Show all example inputs
Inputs used in this example
UnitsMetric
Wall length (m)6
Height above ground (m)0.9
Block length (face) (cm)30
Block height (cm)10
Courses buried below ground1
Extra for waste (%)5
Cap length (0 = no caps) (cm)30
Base trench width (cm)60
Base gravel depth (cm)15
Drainage gravel behind wall (cm)30
Base gravel bulk density (kg/m³)1800
Drainage gravel bulk density (kg/m³)1500
  • Wall blocks including allowance: 210
  • Cap pieces: 20
  • Base volume (m³): 0.54
  • Drain stone volume (m³): 1.8
  • Base mass (metric tonnes): 0.972
  • Drain stone mass (metric tonnes): 2.7

Illustrative project geometry and stated assumptions; not a product endorsement or construction specification.

Example checked on October 22, 2026. Calculation method and limits.

How to use the retaining wall calculator

  1. Enter the wall length and the height that will show above the finished ground.
  2. Enter how many courses are buried below ground. Enter the designed embedment; buried-course quantity does not verify resistance to sliding.
  3. Enter the face size of your blocks and the length of the cap blocks, or 0 if you won't use caps.
  4. Enter the size of the gravel base trench and the width of the drainage gravel behind the wall.

The formulas

Blocks per course = wall length ÷ block length (rounded up) Courses = height above ground ÷ block height (rounded up) + buried courses Blocks = blocks per course × courses × (1 + waste %) Caps = wall length ÷ cap length (rounded up) Base gravel = wall length × trench width × base depth Drainage gravel = wall length × drainage width × total wall height

Worked example

A 20 ft wall standing 3 ft above ground, with 12 × 4 in blocks, one buried course and 12 in caps:

Building tips

Calculation basis, defaults & source review

What this model calculates

Round blocks per course and courses above ground up; add entered buried courses and waste. Aggregate zones use entered rectangular dimensions and separate densities.

Fixed assumptions and limits

  • Gravel density resets: 1660 kg/m³ for base and drainage. Independent planning assumptions, not verified products.

A quantity estimate cannot establish stability or drainage adequacy, including short walls. No sliding, overturning, bearing, global stability or reinforcement design is performed.

Reset inputs for comparison

These are starting values, not a prescription or a record of your current inputs. Your estimate and exported report show the values actually used. Select a matching manufacturer reference or enter exact product data where supported.

ParameterUS reset / unitMetric reset / unitStatus
Wall length20 ft6 mIllustrative project input; not a prescribed value
Height above ground3 ft0.9 mIllustrative project input; not a prescribed value
Courses buried below ground1 1 Illustrative project input; not a prescribed value
Block length (face)12 in30 cmIllustrative project input; not a prescribed value
Block height4 in10 cmIllustrative project input; not a prescribed value
Cap length (0 = no caps)12 in30 cmIllustrative project input; not a prescribed value
Extra for waste5 %5 %Illustrative project input; not a prescribed value
Base trench width24 in60 cmIllustrative project input; not a prescribed value
Base gravel depth6 in15 cmIllustrative project input; not a prescribed value
Drainage gravel behind wall12 in30 cmIllustrative project input; not a prescribed value
Base gravel bulk density103.63041455640004 lb/ft³1660 kg/m³Planning reset; use exact product data
Drainage gravel bulk density103.63041455640004 lb/ft³1660 kg/m³Planning reset; use exact product data

Evidence and applicability

  • CMHA guide to segmental retaining walls — SRW-TEC-005-09 (2009). Retaining-wall systems/design context, not certification of block, embedment or aggregate defaults. Review status: primary indexed guidance reviewed; direct fetch may fail.
  • NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026. Unit definitions and conversion factors only; not material density or product coverage. Review status: primary content reviewed.

Arithmetic, model and source-scope review: 22 October 2026. Indexed-only or access-limited sources are identified explicitly. Review does not verify your measurements, every product or every possible input. Independent professional engineering approval has not been obtained.

Sources and technical limitations

CMHA's retaining-wall guide provides system context. Height alone cannot decide whether engineering is needed: soil, surcharge, slopes, groundwater, boundaries and local rules also matter.

Engineering safety: This tool only estimates materials or selected geometry. It does not check structural adequacy, loads, connections, foundation stability or full building-code compliance. Use a qualified design professional and the locally adopted code before construction.

Frequently asked questions

How many blocks do I need for a 20 ft retaining wall?

With 12 in long, 4 in high blocks, a 20 ft wall 3 ft high with one buried course needs 10 courses of 20 blocks: 200 blocks, or about 210 with 5% extra.

How deep should the first course be buried?

Embedment is site and system specific. Use the approved block-system detail and the project engineer’s requirements; this calculator does not determine it.

How much gravel goes behind a retaining wall?

Many installation guides call for a zone of drainage gravel behind the blocks, often about 12 in wide, for the full height of the wall, with a perforated drain pipe at the bottom.

When does a retaining wall need an engineer?

Ask the local authority and the wall-system designer. Height, surcharge, slopes, soil, groundwater and site boundaries can all trigger a design or permit requirement, including for relatively low walls. This materials tool cannot determine an exemption.

Related calculators