UNDERSTAND THE ESTIMATE
Try a checked example
An 80 m² horizontal roof projection receiving 20 mm of rain has 1,600 L of gross rainfall. An assumed 80% collection efficiency gives 1,280 L. Usable storage may be lower because of tank capacity, first flush, overflow and timing.
Show all example inputs
| Units | Metric |
|---|---|
| Length (m) | 10 |
| Width (m) | 8 |
| Rainfall (mm) | 20 |
| Collection efficiency (%) | 80 |
- Estimated collected water (L): 1280
Illustrative project geometry and stated assumptions; not a product endorsement or construction specification.
Example checked on October 22, 2026. Calculation method and limits.
How to use the rainwater harvesting calculator
- Enter the length and width of the roof area that drains to your gutters, measured as a footprint on the ground. Roof pitch does not change how much rain falls on it.
- Enter the rainfall: one storm to size a barrel, or your annual rainfall (from your national weather service) to estimate yearly supply.
- The reset 90% collection efficiency is illustrative. Select an appropriate value for roof material, first-flush diversion, leakage and overflow.
The formulas
US: gallons = roof area (sq ft) × rainfall (in) × 0.623 × efficiency Metric: liters = roof area (m²) × rainfall (mm) × efficiencyOne inch of rain on one square foot is 144 cubic inches, or 0.623 US gallons. In metric, 1 mm of rain on 1 m² is exactly 1 liter. The University of Arizona Cooperative Extension uses this formula with an efficiency factor of about 0.90 for most roofs.
Worked example
A house with a 40 × 30 ft roof footprint and a 1 in storm:
- Area: 40 × 30 = 1,200 sq ft.
- Water: 1,200 × 1 × 0.623 × 0.90 ≈ 673 gallons.
- That would fill about 13 rain barrels of 55 gallons.
Tips
- A first-flush diverter discards the dirtiest water from the start of each storm.
- Give every tank or barrel an overflow that sends excess water away from your foundation.
- Rules on collecting rainwater differ by state and country, and untreated rainwater is not safe to drink. Check local regulations before installing a system.
Calculation basis, defaults & source review
What this model calculates
Collected water = horizontal catchment × rain depth × efficiency. 1 ft²-inch = 144/231 US gal; metric m² × mm yields liters.
Fixed assumptions and limits
- Efficiency reset: 90%. Regional example assumption, not guaranteed collection efficiency.
- Barrel comparison: 55 US gal. Illustrative container size, not required storage design.
Rainfall period must match the planning question. Tank sizing needs demand, temporal rainfall and first-flush/loss analysis.
Reset inputs for comparison
These are starting values, not a prescription or a record of your current inputs. Your estimate and exported report show the values actually used. Select a matching manufacturer reference or enter exact product data where supported.
| Parameter | US reset / unit | Metric reset / unit | Status |
|---|---|---|---|
| Length | 40 ft | 12 m | Illustrative project input; not a prescribed value |
| Width | 30 ft | 9 m | Illustrative project input; not a prescribed value |
| Rainfall | 1 in | 25 mm | Illustrative project input; not a prescribed value |
| Collection efficiency | 90 % | 90 % | Illustrative project input; not a prescribed value |
Evidence and applicability
- University of Arizona — harvesting rain in Cochise County — Regional web guidance checked 22 October 2026. Roof area × rain depth × efficiency; 0.623 is a rounded conversion and 90% is an illustrative collection efficiency. Review status: primary equation reviewed.
- NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026. Unit definitions and conversion factors only; not material density or product coverage. Review status: primary content reviewed.
Arithmetic, model and source-scope review: 22 October 2026. Indexed-only or access-limited sources are identified explicitly. Review does not verify your measurements, every product or every possible input. Independent professional engineering approval has not been obtained.
Sources and technical limitations
The university extension reference supports catchment planning. The estimate does not establish potability, treatment needs, structural tank support or a permit-compliant plumbing connection.
- University of Arizona — harvesting rain in Cochise County — Regional web guidance checked 22 October 2026
Roof area × rain depth × efficiency; 0.623 is a rounded conversion and 90% is an illustrative collection efficiency. Review: primary equation reviewed.
- NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026
Unit definitions and conversion factors only; not material density or product coverage. Review: primary content reviewed.
Frequently asked questions
How much water can I collect from 1 inch of rain?
About 0.623 gallons per square foot of roof. A 1,000 sq ft roof collects about 623 gallons, or roughly 560 gallons at 90% efficiency.
Does roof pitch affect how much rain I collect?
No. Rain falls vertically, so what matters is the roof's footprint on the ground, not the sloped surface area.
What collection efficiency should I use?
About 90% is typical for most roofs. Use a lower value if your gutters often overflow or you divert the first part of each storm.
How many rain barrels do I need?
Divide the gallons from a typical storm by the barrel size. For a 1,200 sq ft roof and a 1 in storm, that is about 673 gallons, or 13 barrels of 55 gallons.