  1. MeasureEnter your project measurements.
  2. CheckReview units and project assumptions.
  3. ReviewRead the estimate and its limitations.

Your project

Change an input to update the estimate. Check units and product assumptions before ordering.

Units
Roof footprint
Rain

YOUR ESTIMATE

Your estimate

Use the roof's footprint (the area it covers on the ground), not the sloped roof surface. Results are estimates; actual yield depends on gutters, first-flush diverters and storage size.

Detailed drawings & current dimensions

Not to scale. Dimension values follow your inputs; the drawing proportions do not. Displayed numbers may be rounded. This is a measurement aid, not an approved construction detail.

Measurement overview

Measurement overviewSchematic measurement view, not to scale. Lettered dimensions correspond to the current input list. Layer heights and repeated items are illustrative, not design details.Horizontal footprintPitchSlopeUniform-pitch illustration

Current calculator inputs

Hidden shape inputs are omitted. These values are entered assumptions, not independently verified product data.

Keep this estimate

Export the current estimate as a visual report. Print it or save as PDF. Local saving is optional; no account is required.

Back up or restore saved projects

Data files (JSON) are for restoring editable projects, not for reading or printing. They include saved projects only; save the current estimate first if you want it in the backup.

UNDERSTAND THE ESTIMATE

Collected water is different from available supply

Use horizontal catchment projection and rainfall depth for the same period. A millimetre of rain on a square metre is one litre before collection losses.

Efficiency is an input allowance for losses, not a prediction of each storm. First-flush diversion, gutter overflow and tank-full events depend on timing. A yearly rainfall total cannot show whether storage can cover a dry month.

Try a checked example

An 80 m² horizontal roof projection receiving 20 mm of rain has 1,600 L of gross rainfall. An assumed 80% collection efficiency gives 1,280 L. Usable storage may be lower because of tank capacity, first flush, overflow and timing.

Show all example inputs
Inputs used in this example
UnitsMetric
Length (m)10
Width (m)8
Rainfall (mm)20
Collection efficiency (%)80
  • Estimated collected water (L): 1280

Illustrative project geometry and stated assumptions; not a product endorsement or construction specification.

Example checked on October 22, 2026. Calculation method and limits.

How to use the rainwater harvesting calculator

  1. Enter the length and width of the roof area that drains to your gutters, measured as a footprint on the ground. Roof pitch does not change how much rain falls on it.
  2. Enter the rainfall: one storm to size a barrel, or your annual rainfall (from your national weather service) to estimate yearly supply.
  3. The reset 90% collection efficiency is illustrative. Select an appropriate value for roof material, first-flush diversion, leakage and overflow.

The formulas

US: gallons = roof area (sq ft) × rainfall (in) × 0.623 × efficiency Metric: liters = roof area (m²) × rainfall (mm) × efficiency

One inch of rain on one square foot is 144 cubic inches, or 0.623 US gallons. In metric, 1 mm of rain on 1 m² is exactly 1 liter. The University of Arizona Cooperative Extension uses this formula with an efficiency factor of about 0.90 for most roofs.

Worked example

A house with a 40 × 30 ft roof footprint and a 1 in storm:

Tips

Calculation basis, defaults & source review

What this model calculates

Collected water = horizontal catchment × rain depth × efficiency. 1 ft²-inch = 144/231 US gal; metric m² × mm yields liters.

Fixed assumptions and limits

  • Efficiency reset: 90%. Regional example assumption, not guaranteed collection efficiency.
  • Barrel comparison: 55 US gal. Illustrative container size, not required storage design.

Rainfall period must match the planning question. Tank sizing needs demand, temporal rainfall and first-flush/loss analysis.

Reset inputs for comparison

These are starting values, not a prescription or a record of your current inputs. Your estimate and exported report show the values actually used. Select a matching manufacturer reference or enter exact product data where supported.

ParameterUS reset / unitMetric reset / unitStatus
Length40 ft12 mIllustrative project input; not a prescribed value
Width30 ft9 mIllustrative project input; not a prescribed value
Rainfall1 in25 mmIllustrative project input; not a prescribed value
Collection efficiency90 %90 %Illustrative project input; not a prescribed value

Evidence and applicability

  • University of Arizona — harvesting rain in Cochise County — Regional web guidance checked 22 October 2026. Roof area × rain depth × efficiency; 0.623 is a rounded conversion and 90% is an illustrative collection efficiency. Review status: primary equation reviewed.
  • NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026. Unit definitions and conversion factors only; not material density or product coverage. Review status: primary content reviewed.

Arithmetic, model and source-scope review: 22 October 2026. Indexed-only or access-limited sources are identified explicitly. Review does not verify your measurements, every product or every possible input. Independent professional engineering approval has not been obtained.

Sources and technical limitations

The university extension reference supports catchment planning. The estimate does not establish potability, treatment needs, structural tank support or a permit-compliant plumbing connection.

Frequently asked questions

How much water can I collect from 1 inch of rain?

About 0.623 gallons per square foot of roof. A 1,000 sq ft roof collects about 623 gallons, or roughly 560 gallons at 90% efficiency.

Does roof pitch affect how much rain I collect?

No. Rain falls vertically, so what matters is the roof's footprint on the ground, not the sloped surface area.

What collection efficiency should I use?

About 90% is typical for most roofs. Use a lower value if your gutters often overflow or you divert the first part of each storm.

How many rain barrels do I need?

Divide the gallons from a typical storm by the barrel size. For a 1,200 sq ft roof and a 1 in storm, that is about 673 gallons, or 13 barrels of 55 gallons.

Related calculators