Home › Epoxy Floor Calculator

Paint, floors & interior finishes

Epoxy Floor Calculator

Work out how much epoxy or other floor coating you need for a garage, basement or shop floor. Use the coverage printed on the product label, or calculate it from the film thickness and percent solids on the data sheet.

US & metric · No account needed · Calculations stay in your browser

View the measurement guide
Measurement guideNot to scale
Measurement guide for Epoxy Floor CalculatorMeasure floor area and use per-coat coverage, or the selected dry-film thickness and volume solids. All geometry is schematic and does not depict a structural design.LengthWidthFace / areaCoats / coverage
Measure floor area and use per-coat coverage, or the selected dry-film thickness and volume solids. View detailed drawings
  1. MeasureEnter your project measurements.
  2. MatchCheck product values and allowances.
  3. ReviewCheck quantities, inputs and sources.

Your project

Change an input to update the estimate. Check units and product assumptions before ordering.

Units
Coverage
Floor
Coverage from the label
Coverage from the data sheet
Buying
Product value source

In label mode use coverage per coat and total mixed kit volume. In film mode use the selected dry-film thickness and volume solids. Values stay in this tab; reset restores planning assumptions.

YOUR MATERIALS

Purchase estimate

Coverage depends on the product and on how porous the concrete is. Primers and topcoats have their own coverage rates; calculate them separately. Product defaults are planning assumptions. Use the chosen product data sheet or supplier test for the actual application; reset restores defaults.

Detailed drawings & current dimensions

Not to scale. Dimension values follow your inputs; the drawing proportions do not. Displayed numbers may be rounded. This is a measurement aid, not an approved construction detail.

Measurement overview

Measurement overviewSchematic measurement view, not to scale. Lettered dimensions correspond to the current input list. Layer heights and repeated items are illustrative, not design details.LengthWidthFace / areaCoats / coverage

Current calculator inputs

Hidden shape inputs are omitted. These values are entered assumptions, not independently verified product data.

Keep this estimate

Export the current estimate as a visual report. Print it or save as PDF. Local saving is optional; no account is required.

Back up or restore saved projects

Data files (JSON) are for restoring editable projects, not for reading or printing. They include saved projects only; save the current estimate first if you want it in the backup.

UNDERSTAND THE ESTIMATE

Check what a kit's coverage actually means

In label mode, enter coverage per coat and total mixed kit volume. A label stating coverage for a complete two-coat system must not be entered as per-coat coverage and then multiplied by two again.

Film mode estimates theoretical spreading from dry-film thickness and volume solids. It does not include surface-profile filling unless your allowance captures it. Pot life, mixing ratio, substrate moisture and recoat windows still come from the product instructions.

Try a checked example

A 20 m² floor with two coats at an assumed 5 m²/L per coat requires 8 L. Adding 10% loss gives 8.8 L; a hypothetical 5 L mixed kit requires ceil(8.8 ÷ 5) = 2 kits. Use total mixed volume, and follow the product's mixing ratio and permitted film thickness.

Show all example inputs
Inputs used in this example
UnitsMetric
ModeFrom the label
Length (m)5
Width (m)4
Number of coats2
Coverage per coat (m² per L)5
Kit or can size (L)5
Extra for waste and porous concrete (%)10
  • Floor area (m²): 20
  • Mixed coating including allowance (L): 8.8
  • Whole 5 L kits: 2

Illustrative project geometry and stated assumptions; not a product endorsement or construction specification.

Example checked on October 22, 2026. Calculation method and limits.

How to use the epoxy floor calculator

  1. Enter the length and width of the floor and the number of coats.
  2. Choose From the label and enter the coverage per coat printed on the kit, for example 250 sq ft per gallon.
  3. Or choose From film thickness and enter the dry film thickness and volume solids from the product data sheet.
  4. Enter the size of the kit or can you will buy.

The formulas

Coverage (sq ft per gal) = 1,604 × volume solids ÷ dry film thickness (mils) Coverage (m² per L) = 1,000 × volume solids ÷ dry film thickness (µm) Coating needed = floor area × coats ÷ coverage × (1 + waste %) Wet film thickness = dry film thickness ÷ volume solids

The number 1,604 comes from the size of a US gallon: 231 cubic inches spread 1 mil (0.001 in) thick covers 231,000 square inches, or 1,604 sq ft. In metric, 1 liter spread 1 µm thick covers 1,000 m². Coating manufacturers use the same formula to work out the coverage on their data sheets.

Volume solids is the part of the coating that stays on the floor after the water or solvent evaporates. A 100% solids epoxy dries to the same thickness it was applied at. A 50% solids coating applied 10 mils wet dries to 5 mils.

Worked example

A 24 × 24 ft two-car garage (576 sq ft) with two coats:

Tips

Calculation basis, defaults & source review

What this model calculates

Label mode: area × coats / per-coat coverage. Film mode: volume from dry thickness / volume-solids fraction. Add loss once and round mixed-volume kits up.

Fixed assumptions and limits

  • Film identity: 1 US gal at 1 mil = 1604.1667 ft²; 1 L at 1 µm = 1000 m². Geometric theoretical coverage before application losses.

Volume solids is not weight solids. Dry thickness is per coat; kit volume means combined usable mixed components. Do not add label and film-mode quantities.

Reset inputs for comparison

These are starting values, not a prescription or a record of your current inputs. Your estimate and exported report show the values actually used. Select a matching manufacturer reference or enter exact product data where supported.

ParameterUS reset / unitMetric reset / unitStatus
Length24 ft7 mIllustrative project input; not a prescribed value
Width24 ft7 mIllustrative project input; not a prescribed value
Number of coats2 2 Illustrative project input; not a prescribed value
Coverage per coat250 sq ft per gal6 m² per LPlanning reset; use exact product data
Dry film thickness per coat10 mils250 µmPlanning reset; use exact product data
Volume solids100 %100 %Planning reset; use exact product data
Kit or can size1 gal5 LPlanning reset; use exact product data
Extra for waste and porous concrete10 %10 %Illustrative project input; not a prescribed value

Evidence and applicability

  • Sherwin-Williams MACROPOXY 646 Fast Cure Epoxy Mastic — Revised September 23, 2026, reference 1101-1, page 1. Mixed Mill White example: nominal 72% ±2% volume solids, 5–10 mil DFT, approximately 115–230 ft²/US gal. Published theoretical figures are rounded; this is not a default or endorsement for every epoxy. Review status: primary product PDF reviewed.
  • NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026. Unit definitions and conversion factors only; not material density or product coverage. Review status: primary content reviewed.

Arithmetic, model and source-scope review: 22 October 2026. Indexed-only or access-limited sources are identified explicitly. Review does not verify your measurements, every product or every possible input. Independent professional engineering approval has not been obtained.

Sources and technical limitations

The coating datasheet is an example of product-specific solids and spreading data. It is not a default specification or an endorsement that every epoxy can be applied at an entered thickness.

Frequently asked questions

How much epoxy do I need for a two-car garage?

A 24 × 24 ft garage is 576 sq ft. With two coats of a product that covers 250 sq ft per gallon, you need about 4.6 gallons, or about 5.1 gallons with 10% extra.

What is a mil?

A mil is one thousandth of an inch (0.001 in), or 25.4 micrometers (µm). Coating thickness is usually given in mils in the US and in µm elsewhere.

What does volume solids mean?

It is the percentage of the coating, by volume, that remains as a dry film once the water or solvent has evaporated. Lower solids means a thinner dry film from the same amount of liquid.

Why did my first coat use more epoxy than expected?

Concrete is porous, and the first coat fills the surface pores. That is why the calculator adds extra for waste and porous concrete.

Related calculators

Browse all calculators by task