UNDERSTAND THE ESTIMATE
Try a checked example
A 20 m² floor with two coats at an assumed 5 m²/L per coat requires 8 L. Adding 10% loss gives 8.8 L; a hypothetical 5 L mixed kit requires ceil(8.8 ÷ 5) = 2 kits. Use total mixed volume, and follow the product's mixing ratio and permitted film thickness.
Show all example inputs
| Units | Metric |
|---|---|
| Mode | From the label |
| Length (m) | 5 |
| Width (m) | 4 |
| Number of coats | 2 |
| Coverage per coat (m² per L) | 5 |
| Kit or can size (L) | 5 |
| Extra for waste and porous concrete (%) | 10 |
- Floor area (m²): 20
- Mixed coating including allowance (L): 8.8
- Whole 5 L kits: 2
Illustrative project geometry and stated assumptions; not a product endorsement or construction specification.
Example checked on October 22, 2026. Calculation method and limits.
How to use the epoxy floor calculator
- Enter the length and width of the floor and the number of coats.
- Choose From the label and enter the coverage per coat printed on the kit, for example 250 sq ft per gallon.
- Or choose From film thickness and enter the dry film thickness and volume solids from the product data sheet.
- Enter the size of the kit or can you will buy.
The formulas
Coverage (sq ft per gal) = 1,604 × volume solids ÷ dry film thickness (mils) Coverage (m² per L) = 1,000 × volume solids ÷ dry film thickness (µm) Coating needed = floor area × coats ÷ coverage × (1 + waste %) Wet film thickness = dry film thickness ÷ volume solidsThe number 1,604 comes from the size of a US gallon: 231 cubic inches spread 1 mil (0.001 in) thick covers 231,000 square inches, or 1,604 sq ft. In metric, 1 liter spread 1 µm thick covers 1,000 m². Coating manufacturers use the same formula to work out the coverage on their data sheets.
Volume solids is the part of the coating that stays on the floor after the water or solvent evaporates. A 100% solids epoxy dries to the same thickness it was applied at. A 50% solids coating applied 10 mils wet dries to 5 mils.
Worked example
A 24 × 24 ft two-car garage (576 sq ft) with two coats:
- With a label coverage of 250 sq ft per gallon: 576 × 2 ÷ 250 = 4.6 gal, plus 10% = about 5.1 gallons.
- With a 100% solids epoxy at 10 mils per coat: coverage = 1,604 × 1.00 ÷ 10 = 160 sq ft per gallon, so 576 × 2 ÷ 160 = 7.2 gal, plus 10% = about 7.9 gallons.
Tips
- Bare or newly ground concrete soaks up part of the first coat, so it often covers less than the label says.
- Mixed epoxy has a limited pot life. Mix only as much as you can spread in that time.
- Follow the manufacturer's instructions for cleaning, profiling and moisture-testing the concrete, and for the temperature range during application.
- Decorative flakes and anti-slip additives are sold separately. Check their coverage on the package.
Calculation basis, defaults & source review
What this model calculates
Label mode: area × coats / per-coat coverage. Film mode: volume from dry thickness / volume-solids fraction. Add loss once and round mixed-volume kits up.
Fixed assumptions and limits
- Film identity: 1 US gal at 1 mil = 1604.1667 ft²; 1 L at 1 µm = 1000 m². Geometric theoretical coverage before application losses.
Volume solids is not weight solids. Dry thickness is per coat; kit volume means combined usable mixed components. Do not add label and film-mode quantities.
Reset inputs for comparison
These are starting values, not a prescription or a record of your current inputs. Your estimate and exported report show the values actually used. Select a matching manufacturer reference or enter exact product data where supported.
| Parameter | US reset / unit | Metric reset / unit | Status |
|---|---|---|---|
| Length | 24 ft | 7 m | Illustrative project input; not a prescribed value |
| Width | 24 ft | 7 m | Illustrative project input; not a prescribed value |
| Number of coats | 2 | 2 | Illustrative project input; not a prescribed value |
| Coverage per coat | 250 sq ft per gal | 6 m² per L | Planning reset; use exact product data |
| Dry film thickness per coat | 10 mils | 250 µm | Planning reset; use exact product data |
| Volume solids | 100 % | 100 % | Planning reset; use exact product data |
| Kit or can size | 1 gal | 5 L | Planning reset; use exact product data |
| Extra for waste and porous concrete | 10 % | 10 % | Illustrative project input; not a prescribed value |
Evidence and applicability
- Sherwin-Williams MACROPOXY 646 Fast Cure Epoxy Mastic — Revised September 23, 2026, reference 1101-1, page 1. Mixed Mill White example: nominal 72% ±2% volume solids, 5–10 mil DFT, approximately 115–230 ft²/US gal. Published theoretical figures are rounded; this is not a default or endorsement for every epoxy. Review status: primary product PDF reviewed.
- NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026. Unit definitions and conversion factors only; not material density or product coverage. Review status: primary content reviewed.
Arithmetic, model and source-scope review: 22 October 2026. Indexed-only or access-limited sources are identified explicitly. Review does not verify your measurements, every product or every possible input. Independent professional engineering approval has not been obtained.
Sources and technical limitations
The coating datasheet is an example of product-specific solids and spreading data. It is not a default specification or an endorsement that every epoxy can be applied at an entered thickness.
- Sherwin-Williams MACROPOXY 646 Fast Cure Epoxy Mastic — Revised September 23, 2026, reference 1101-1, page 1
Mixed Mill White example: nominal 72% ±2% volume solids, 5–10 mil DFT, approximately 115–230 ft²/US gal. Published theoretical figures are rounded; this is not a default or endorsement for every epoxy. Review: primary product PDF reviewed.
- NIST — revised unit conversion factors — International foot definitions; web reference checked 22 October 2026
Unit definitions and conversion factors only; not material density or product coverage. Review: primary content reviewed.
Frequently asked questions
How much epoxy do I need for a two-car garage?
A 24 × 24 ft garage is 576 sq ft. With two coats of a product that covers 250 sq ft per gallon, you need about 4.6 gallons, or about 5.1 gallons with 10% extra.
What is a mil?
A mil is one thousandth of an inch (0.001 in), or 25.4 micrometers (µm). Coating thickness is usually given in mils in the US and in µm elsewhere.
What does volume solids mean?
It is the percentage of the coating, by volume, that remains as a dry film once the water or solvent has evaporated. Lower solids means a thinner dry film from the same amount of liquid.
Why did my first coat use more epoxy than expected?
Concrete is porous, and the first coat fills the surface pores. That is why the calculator adds extra for waste and porous concrete.